Mene ne Waya Mai Ja Kabulu?
Winc ɗin cire waya na injiniya ne wanda aka tsara don cirewa, ɗagawa, ko tashin hankali nauyi ta amfani da waya ko igiya a kusa da drum. Waɗannan injunan suna da mahimmanci a cikin wuraren gini, kayan aikin lantarki, ayyukan kayan aikin sadarwa, da wuraren masana'antu. Winc ɗin yana canza ƙarfin juyawa daga shigarwar mota ko na hannu zuwa ƙarfin jan layi, yana bawa ma'aikata damar motsa wayoyi, wayoyi, kwantena, da sauran kayan nauyi ta hanyar sarari, ta hanyar nisa mai tsawo, ko sama tsaye inda ƙoƙarin hannu zai zama mara amfani ko haɗari.
Wins ɗin da ke jan igiya na zamani sun fara daga ƙananan raka'a masu ɗaukar hoto waɗanda aka tsara don aikin lantarki mai ƙarancin ƙarfin lantarki zuwa manyan samfuran masana'antu waɗanda ke iya jan tarin ton. Ba tare da la'akari da girman su ba, duk winches suna da gine-gine iri ɗaya: drum wanda ke adana da kuma jujjuya kebul ɗin, tsarin birki don sarrafa saukowar kaya da riƙe tashin hankali, tsarin tuki (da hannu, lantarki, na'ura mai aiki da karfin ruwa, ko na iska), da kuma firam wanda ke tallafawa tarawa. Zaɓin nau'in winch ya dogara da dalilai kamar nauyin kaya, nesa mai jan hankali, tushen wutar lantarki da ke akwai, da yanayin muhalli.
Abubuwan da Suka Sauke da Kuma Yadda Suke Aiki
Fahimtar muhimman abubuwan da ke cikin igiyar waya na taimaka wa masu aiki su yi amfani da kayan aiki yadda ya kamata kuma su gano matsalolin da za su iya faruwa kafin su haifar da rashin aiki.
Taron Drum da Cable
Drum shine ɓangaren silinda wanda aka yi wa kebul ɗin. Drum dole ne a daidaita girman girmansa daidai don diamita da tsawon kebul don hana murkushewa ko ɓarkewa mara daidaito. Kayan da kansa yawanci igiya ce ta waya ta ƙarfe ko igiya ta roba.
Tsarin Motar da Tsarin Gudanarwa
Wins na lantarki sune mafi yawan amfani a cikin aikace-aikacen jirgi, ta amfani da AC ko DC motors don tuka drum ta hanyar tsarin rage kayan aiki. Wins na hydraulic suna ba da babban karfin juyi da kuma sarrafawa mai santsi, yana mai da su dace da amfani da masana'antu masu nauyi. Wins na pneumatic ana amfani da su a cikin yanayin fashewa inda ƙarancin lantarki ke haifar da haɗari. Wins na hannu suna dogara da cranking na hannu kuma sun dace da ɗaukar nauyi ko amfani da lokaci-lokaci inda ba a sami wutar lantarki.
Tsarin Braking
Kowane abin hawa dole ne ya sami ingantaccen tsarin birki don riƙe nauyin tsayawa da saukowa. Brakes na inji suna aiki ta atomatik lokacin da aka cire wutar, yana ba da aiki mai aminci. Tsarin birki mai ƙarfi yana amfani da juriya ta lantarki don sarrafa saurin yayin saukarwa. Masu aiki dole ne su gwada birki kowace rana kuma kada su ɗauka cewa suna aiki ba tare da tabbatarwa ba.
Tsarin Kulawa
Gudanar da nesa yana ba masu aiki damar tsayawa a nesa mai aminci yayin ayyukan janyewa. Dandalin waya da na'urorin sarrafa rediyo mara waya dukansu gama gari ne. Tsarin zamani galibi sun haɗa da saka idanu kan kaya, sauya iyaka, da ayyukan dakatar da gaggawa waɗanda ke yanke wutar lantarki nan take.
Nau'in Wink na Fitar da Kabulu
Zaɓin abin da ya dace don aiki na bukatar sanin manyan rukunoni da kuma aikace-aikacen su na yau da kullum.
Waya mai jan igiyar lantarki
Ana amfani da winciken lantarki a cikin sadarwa da aikin lantarki mai ƙarancin ƙarfin lantarki. Suna haɗa su zuwa tashoshin wutar lantarki na yau da kullun ko janareto kuma suna ba da ikon sarrafa saurin canji.
Waya mai jan igiyar ruwa
Wins na lantarki suna motsawa ta hanyar famfo na lantarki wanda ke aiki da injin daban ko tsarin PTO na abin hawa. Suna da kyau a aikace-aikace masu ƙalubale kamar jan wayoyin amfani ta hanyar tashar karkashin kasa, shigar da layin watsa nauyi, ko dawo da motoci. Tsarin hydraulic yana ba da santsi, madaidaiciyar saurin canzawa kuma yana iya kiyaye cikakken karfin juyi a ƙananan gudu.
Waya mai jan igiyar iska
Ana amfani da winches da ke amfani da iska a cikin yanayin da ƙuƙwalwar lantarki za ta iya ƙone gas ko ƙura. Suna da yawa a cikin masana'antun sarrafa man fetur, masana'antun sinadarai, da wuraren sarrafa hatsi. Winches na iska suna da ƙaranci kuma suna da sauƙi amma suna buƙatar isar da iska mai matsi kuma suna haifar da amo fiye da samfuran lantarki.
Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙ
Winches na hannu suna da sauƙi, masu ƙarfi, kuma ba sa buƙatar tushen wutar lantarki na waje. Suna da amfani ga ayyukan janyewa na yau da kullun, wurare masu nisa, ko kayan aiki na madadin. Winches na hannu yawanci suna da ƙananan ƙarfin janyewa da saurin aiki, amma suna ba da cikakken iko da ƙananan farashin kulawa.
Gwanin Gwanin Gwanin Gwanin Gwanin Gwanin Gwanin Gwanin Gwanin Gwanin Gwanin Gwanin Gwanin Gwanin Gwanin Gwanin Gwanin Gwanin Gwanin Gwanin Gwanin Gwanin Gwanin Gwanin Gwanin Gwanin Gwanin Gwanin Gwanin Gwanin Gwanin Gwanin Gwanin Gwanin Gwanin Gwanin Gwanin Gwanin Gwanin Gwanin Gwanin Gwanin Gwanin Gwanin Gwanin Gwanin Gwanin Gwanin Gwanin Gwanin Gwanin Gwanin Gwanin Gwanin Gwanin Gwanin Gwanin Gwanin Gwanin Gwanin Gwanin Gwanin Gwanin Gwanin Gwanin Gwanin Gwanin Gwanin Gwanin Gwanin Gwanin Gwanin Gwanin Gwanin Gwanin Gwanin Gwanin Gwanin Gwanin Gwanin Gwanin Gwanin Gwanin Gwanin Gwanin
Capstan winch yana amfani da madauri mai juyawa tare da farfajiyar ƙasa, kuma ana kunsa kebul a kusa da madauri sau da yawa maimakon a mirgine shi. Wannan ƙirar tana ba da damar janyewa ba tare da zaren ya tara a kan madauri ba.
Muhimman Abubuwan Tsaro
Amma, idan aka yi amfani da igiyoyi don yin amfani da igiyoyi, dole ne a yi amfani da su don yin amfani da su don yin amfani da su.
Binciken da ya gabata
Ka duba igiyar kafin ka yi amfani da ita. Ka duba igiyar kafin ka yi amfani da ita. Ka duba igiyar kafin ka ga cewa ta yi karkacewa, ko ta yi amfani da ita a cikin akwatin tsuntsu, ko ta yi amfani da ita a cikin akwatin, ko ta yi amfani da ita a cikin akwatin. Ka duba ƙusa da ƙusa don ganin cewa ta yi karkacewa, ko ta yi karkacewa, ko kuma ta lalace. Ka duba cewa ƙusa tana juyawa a hankali kuma cewa ta yi amfani da ita yadda ya kamata. Ka duba don ganin cewa akwai ruwa mai ruwa, ko kuma igiyar lantarki da ta yi karkace, ko kuma ga ƙusa.
Kayan Kariya na Musamman
Masu aiki da ma'aikatan da ke kusa dole ne su sa PPE mai dacewa. Wannan ya haɗa da safofin hannu masu jurewa don kare hannayensu daga burrs da splinters na igiya, tabarau na tsaro ko tabarau don karewa daga ɓarnar tashi idan igiya ta fashe, takalma mai ƙafar ƙarfe don kare ƙafa daga sauke kaya ko komawar igiya, da kuma hataye masu ƙarfi a wuraren da ke da haɗari a sama. Kariya ta ji tana da mahimmanci lokacin da ake aiki da manyan hawan lantarki ko na iska. Watsun gani mai ƙarfi suna taimakawa wajen kula da hankali a wuraren aiki masu aiki.
Tsaron Yanki da Sadarwa
Kafa yankin aiki mai sarrafawa a kusa da winch da hanyar janyewa. toshe yankin tare da cones, tef, ko alamomi don kiyaye ma'aikatan da ba a ba da izini ba. Sanya masu lura a wurare masu mahimmanci inda kewayawar ke canzawa ko kuma inda ma'aikata zasu iya yin ɗorawa. Kafa siginar hannu mai haske ko sadarwar rediyo tsakanin mai sarrafa winch da mai lura a wurin ɗaukar kaya. Kada kowa ya shiga yankin tashin hankali yayin da winch ke ƙarƙashin ɗaukar kaya.
Ƙarfin Nauyin da Ƙarfin Ƙarfin Ƙarfin
Kada ku wuce ƙarfin janyewar da aka ƙayyade na winch. Matsayin ya shafi layin farko na kebul a kan drum; ƙarfin janyewa yana raguwa yayin da ake ƙara ƙarin layin kebul saboda sauye-sauyen ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin. Yi la'akari da friction, lankwasawa a cikin hanyar kebul, da kowane kusurwa da ke ƙara ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin
Tsarin Aiki Mai Amfani
Biye da tsari mai kyau, tsarin da aka tsara zai rage hadarin hadarin hadari kuma ya tabbatar da aiki mai kyau.
Shirya Yadda Za a Yi Fitar
Yi nazarin duk hanyar kebul kafin farawa. Gano gefuna masu kaifi, kusurwa masu tsauri, ko wuraren da za su iya lalata kebul ko haifar da matsi. Ka ƙayyade shugabancin janyewa kuma tabbatar da cewa an sanya winch don samar da jan layi mai madaidaiciya gwargwadon iko. Yi la'akari da tsawon hanyar kebul, canje-canje a tsawo, da duk wani matsakaici na tsakiya. Yi lissafin ƙarfin janyewar da ake buƙata bisa la'akari da nauyin kebul, ma'aunin jujjuyawar, da kuma yanayin hanya.
Yadda Za a Kafa Winka
Ka sanya abin da aka yi amfani da shi a kan ƙasa mai kyau. Ka sanya shi a ƙasa mai kyau. Ka kiyaye shi daga motsi ta hanyar buga ƙafafun, ta amfani da kayan motsawa, ko kuma ka haɗa shi zuwa tushe mai ƙarfi. Waya mara kyau na iya juyawa ko zamewa lokacin da aka yi amfani da tashin hankali. Ka haɗa da abin da aka yi amfani da shi zuwa tushen wutar lantarki mai dacewa kuma ka tabbatar cewa duk abubuwan sarrafawa suna aiki daidai. Ka tabbata cewa an isa ga tsayawar gaggawa kuma an gwada shi.
Yadda Za a Saka Kabel
Yi amfani da kayan aiki masu dacewa kamar sarƙoƙi, ƙuƙwalwa, da ƙuƙwalwa tare da iyakar nauyin aiki wanda ya wuce nauyin da ake tsammani. Kada ku ɗaura ƙuƙwalwa a cikin igiyar waya. Tabbatar da cewa an yi igiyar haƙa daidai a kan drum ba tare da ƙetare ko rata ba. Aƙalla ƙuƙwalwar igiya uku zuwa biyar dole ne su kasance a kan drum a kowane lokaci don hana haɗewar igiyar daga janyewa.
Farawa da Gudun Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙar
Ka fara jan a jinkirin gudu don ɗaukar sassauci a hankali. Jerky farawa na iya buga tsarin da kuma haifar da gazawar kebul ko lalacewar bangare. Yayin da kaya ya ɗauki tashin hankali, ƙara saurin a hankali yayin lura da tashin hankali na kebul, daidaita kebul, da kuma rawar drum. Yi hankali da alamun matsala: kebul yana tonowa cikin flange na drum, rashin daidaituwa, zafi mai yawa, amo mara kyau, ko motsi na kaya wanda ya ɓace daga hanyar da aka tsara.
Kulawa a Lokacin Aiki
Idan an yi amfani da na'urar, dole ne a yi amfani da madubi, kyamarori, ko kuma wasu masu lura idan ba a iya ganin nauyin kai tsaye ba. Kada ka bar abin da ke motsawa ba tare da kulawa ba yayin da yake ƙarƙashin tashin hankali. Idan igiyar ta fara yin rikici, ƙwanƙwasa ƙwanƙwasa ta zama ba ta dace ba, ko kuma injin na yin amfani da na'urar ya yi aiki sosai, dakatar nan da nan ka bincika.
Dakatar da Aikin da Aka Saka
Lokacin da kaya ya isa inda yake, kunna birki kuma kulle drum idan wink yana da tsarin kulle. Cire tashin hankali a hankali ta hanyar juya wink a hankali kafin cire igiyar. Kada ku kusanci kaya ko kebul yayin da tashin hankali yake har yanzu. Bayan cire haɗin, sake mirgine kebul ɗin a kan drum don hana kinks da lalacewa yayin ajiya.
Kulawa da Adanawa
Yin aikin da aka yi a kai a kai yana sa igiyoyin da ke jan igiyoyi su yi aiki sosai kuma yana hana su yin rashin aiki da ba a yi tsammani ba.
Kulawa ta Yau da kullum
Bayan amfani da shi, ka goge shi don ka cire datti, mai da danshi. Ka bincika igiyar don ka ga lalacewa kuma ka shafa ta bisa ga takamaiman masana'anta. Ka bincika matakan ruwa a cikin kayan aikin lantarki kuma ka bincika ko akwai ruwa. Ka tabbata cewa duk hanyoyin haɗin lantarki suna da tsabta kuma suna da ƙarfi. Ka gwada aikin dakatar da wutan da kuma aikin gaggawa.
Kulawa a Lokaci-lokaci
A kowane wata ko bayan kowane sa'o'i 100 na aiki, yi cikakken dubawa. Cire kebul ɗin kuma bincika drum don lalacewa ko lalacewa. Bincika lalacewa, kaya, da kayan aiki don dacewa da lubrication da alamun lalacewa. Auna diamita na kebul a wurare da yawa don gano ɓoyayyun lalacewar ciki. maye gurbin wayoyi waɗanda ke nuna raguwa fiye da 10% a diamita ko kuma suna da zaren da aka karya. Bincika duk bolts da fasteners don ƙuntatawa.
Adanawa na Dā
Idan ka ajiye wani abu a cikin wani wuri mai tsawo, ka tsabtace shi sosai kuma ka shafa mai mai mai a kan farfajiyar ƙarfe don ka hana rufi. Ka ajiye shi a cikin yanayi mai bushe, mai kula da yanayi, nesa da hasken rana kai tsaye, ruwan sama, da kuma matsanancin zafin jiki. Ya kamata a ajiye igiyoyin roba daga hasken UV da sinadarai. Ka rufe abin da ke cikin gida da wani kayan shafawa don ka hana ƙura ta fita yayin da kake barin danshi ya fita. Ka cire batura daga kayan aikin lantarki don ka hana lalata.
Yin Rikodi
Ka rubuta tarihin kowane jirgin ruwa a cikin jirgin ruwanka. Ka rubuta kwanakin dubawa, aikin da aka yi, maye gurbin igiyoyi, gyare-gyare, da kuma wasu abubuwan da suka faru. Wannan takardun ya goyi bayan da'awar garanti, ya nuna bin ƙa'idodin aminci, kuma ya taimaka wajen gano matsalolin da suka sake faruwa da za su iya nuna cewa ana bukatar maye gurbin kayan aiki ko kuma sake horar da mai aiki.
Kuskuren da Mutane Suka Yi Kuma Yadda Za Mu Guje Su
Ko da masu yin amfani da kayan aiki da suka ƙware za su iya yin abin da zai iya sa su yi haɗari sosai.
Ƙarfi na Ƙarfin Ƙarfin Ƙarfin Ƙarfin Ƙarfin Ƙarfin Ƙarfin Ƙarfin Ƙarfin Ƙarfin Ƙarfin Ƙarfin Ƙarfin Ƙarfin Ƙarfin Ƙarfin Ƙarfin Ƙarfin Ƙarfin Ƙarfin Ƙarfin Ƙarfin Ƙarfin Ƙarfin Ƙarfin Ƙarfin Ƙarfin Ƙarfin Ƙarfin Ƙarfin Ƙarfin Ƙarfin Ƙarfin Ƙarfin Ƙarfin Ƙarfin Ƙarfin Ƙarfin Ƙarfin Ƙarfin Ƙarfin Ƙarfin Ƙarfin Ƙarfin Ƙarfin Ƙarfin Ƙarfin Ƙarfin Ƙarfin Ƙarfin Ƙarfin Ƙarfin Ƙarfin Ƙarfin Ƙarfin Ƙarfin Ƙarfin Ƙarfin Ƙarfin Ƙarfin Ƙarfin Ƙarfin Ƙarfin Ƙarfin Ƙarfin Ƙarfin Ƙarfin Ƙarfin Ƙarfin Ƙarfin Ƙarfin Ƙarfin Ƙarfin Ƙarfin Ƙarfin Ƙarfin Ƙarfin Ƙarfin Ƙarfin Ƙarfin Ƙarfin Ƙarfin Ƙarfin Ƙar
Mafi haɗari kuskure ne jan kaya da ya wuce na winch ta rated iyawa. Operators iya zama jarabce su matsa iyaka domin ceton lokaci, amma sakamakon zai iya zama bala'i na kebul gazawar, tsarin rushewa, ko winch lalacewa. Koyaushe tabbatar da kaya nauyi, factor a cikin matakai karfi, da kuma amfani da dace winch ga aikin.
Rashin Daidaitaccen Kayan Waya
Idan aka bar igiyar ta ratsa kanta a kan drum, hakan zai haifar da tashin hankali, lalacewar igiya, da kuma yiwuwar tsangwama. Horar da masu aiki su mirgine igiyar ta hanyar daidaitawa ta amfani da tsarin iska mai sauƙi ko jagorar hannu a ƙananan tashin hankali. Bincika mirgina lokaci-lokaci yayin aiki kuma dakatar da gyara matsalolin nan da nan.
Yin watsi da Yanayin Muhalli
Rain, dusar ƙanƙara, laka, da matsanancin zafin jiki suna shafar aikin winch da amincin kebul. Yanayin zafi yana rage friction kuma yana iya haifar da igiyoyin roba su zame a kan drum.
Kawai Ka Yi Tsallake Binciken da Ke Gaban Aiki
Idan lokaci ya yi tsawo, dubawa ne sau da yawa mataki na farko da za a yi watsi da shi. Wannan tattalin arzikin ƙarya yana haifar da gazawar kayan aiki wanda ke haifar da jinkiri da haɗari masu yawa.
Rashin Sadarwa
Idan aka yi amfani da siginar hannu ko rediyo na biyu, ka tabbatar da fahimtarka kafin ka fara janyewa. Idan ka rasa sadarwa, ka dakatar da abin da ke cikin waya nan da nan har sai an sake kafa shi.
Horarwa da Takaddun shaida
Ayyukan winch mai aminci ba shi da hankali. Yana buƙatar horo na yau da kullun wanda ya ƙunshi ilimin kayan aiki na musamman, gane haɗari, da kuma amsa gaggawa. Masu gudanar da jiragen ruwa ya kamata su tabbatar da cewa kowane mutumin da ke aiki da igiyar igiyar waya yana karɓar horo kafin a ba shi damar aiki da kansa.
Batutuwa na Koyarwa da Ya Kamata
Ya kamata shirye-shiryen horo na yau da kullum su haɗa da nau'ikan winch da sassan, zaɓar da dubawa na igiyoyi, ƙididdigar kayan aiki, lissafin kaya, hanyoyin aiki masu aminci, hanyoyin dakatar da gaggawa, da kuma hanyoyin kulawa. Ayyukan hannu a ƙarƙashin kulawa suna da mahimmanci don gina ƙwaƙwalwar ƙwaƙwalwa da amincewa. Ya kamata a gudanar da horo na sabuntawa kowace shekara ko duk lokacin da aka gabatar da sabon kayan aiki a cikin jirgi.
Zaɓuɓɓukan takaddun shaida
Ƙungiyoyi da yawa suna ba da shirye-shiryen takaddun shaida ga masu aiki da winch. Hukumar Hukumar Kula da Takaddun shaida ta Kasa ta Masu Gudanar da Cire (NCCCO) tana ba da takaddun shaida na rigging da na siginar da suka shafi ayyukan winch. Ƙungiyar Ƙungiyar Injiniyoyin Gudanar da Ayyuka ta Duniya (IUOE) da wasu masana'antun suna ba da horo na musamman na winch. Duk da cewa takaddun shaida ba koyaushe ake buƙata ta doka ba, yana nuna ƙwarewa kuma yana iya rage ɗaukar nauyi.
Hakkin Mai Kula
Dole ne masu kula su tabbatar da cewa kawai ma'aikata masu horarwa da izini ne ke aiki da winc. Ya kamata su gudanar da lura na yau da kullun na ayyukan don tabbatar da cewa an bi hanyoyin. Lokacin da aka lura da ayyukan da ba su da aminci, masu kula dole ne su shiga tsakani nan da nan kuma su ba da umarnin gyara. Al'adun aminci suna farawa da jagoranci wanda ke ba da fifiko ga hanyoyin da suka dace fiye da sauri.
Ƙarshen
Wins ɗin da ke jan igiyoyi kayan aiki ne masu ƙarfi waɗanda ke sa aiki mai nauyi ya zama mai inganci da aiki a cikin masana'antu da yawa. Amma ƙarfin su yana buƙatar girmamawa. Kowane mai aiki dole ne ya fahimci kayan aikin da suke amfani da su, ya bi ƙa'idodin aminci da aka kafa, kuma ya himmatu ga kiyayewa na yau da kullun. Daga zaɓar nau'in wins ɗin da ya dace da bincika shi kafin amfani zuwa tsara janyewa da sadarwa a sarari tare da ma'aikatan, kowane mataki yana da mahimmanci.
Ko kana saka igiyar fiber ta hanyar ginin ko kuma kana saka layin watsawa a cikin ƙasa mai tsawo, ka san kayan aikinka, ka tsara aikinka, ka kasance a faɗake, kuma kada ka yi watsi da aminci.
Ta bin jagororin da ke cikin wannan labarin, masu gudanar da jiragen ruwa da ma'aikatan filin za su iya rage haɗari, tsawaita rayuwar kayan aiki, da kammala ayyukan tare da ƙwarewa da amincewa. Don ƙarin albarkatu, tuntuɓi ƙa'idodin rigging da ɗaga OSHA, Hukumar Fasahar Ruwa ta Wire don jagororin kula da kebul, da kuma jagorar sabis na masana'antar ku don takamaiman umarnin samfurin. Taron tuntuɓar masana masana'antu da ci gaba da ilimi zai sa ƙungiyar ku ta kasance a gaba a cikin aikin aminci na winch.