Fahimtar Yanayin shigar da kebul na bayanai
Tabbatar da wayoyin sadarwa na yau da kullun a cikin ofisoshin kasuwanci da gidaje. Ko kuna gudanar da Cat6a don LAN na ofis mai sauri ko kuma janye RG6 don gidan wasan kwaikwayo, aikin yana buƙatar kulawa da daki-daki, bin kyawawan halaye na aminci, da sanin ƙa'idodin masana'antu. Wannan jagorar yana ba da cikakkiyar hanyar, mataki-mataki don ɗaukar bayanai da shigar da wayoyin sadarwa, daga shiri har zuwa tabbatarwa ta ƙarshe. Bin waɗannan hanyoyin zai kare ma'aikata, hana lalacewar tsadaccen igiyar waya, da kuma tabbatar da amincin sigina don shekaru masu zuwa.
A cikin hanyar sadarwa, ana iya samun bayanai da yawa daga cikin hanyoyin sadarwa na lantarki, wanda ke da amfani da wayoyin sadarwa na lantarki, wanda ke da amfani da wayoyin sadarwa na lantarki, wanda ke da amfani da wayoyin sadarwa na lantarki, wanda ke da amfani da wayoyin sadarwa na lantarki, wanda ke da amfani da wayoyin sadarwa na lantarki, wanda ke da amfani da wayoyin sadarwa na lantarki, wanda ke da amfani da wayoyin sadarwa na lantarki, wanda ke da amfani da wayoyin sadarwa na lantarki, wanda ke da amfani da wayoyin sadarwa na lantarki, wanda ke da amfani da wayoyin sadarwa na lantarki, da kuma na lantarki.
Kayan Aiki da Kayan Aiki da Ake Bukata
Kafin aikin ya fara, ka tattara cikakken kayan aiki. Rashin kayan aiki mai mahimmanci a tsakiyar aiki na iya haifar da gaggawa, gajerun hanyoyi marasa lafiya. Jerin da ke ƙasa ya ƙunshi abubuwa masu mahimmanci ga kayan aiki na kasuwanci da na gida.
- Rules na Cable Zaɓi nau'in da ya dace (Cat5e, Cat6, Cat6a, Cat7, Coaxial, ko fiber optic) bisa ga bukatun saurin cibiyar sadarwa da nisa.
- FLT:0]]Tape na kifi ko mai jan igiyar ruwa Don jagorantar kebul ta bango, rufi, da bututu. Ana ba da shawarar faifan kifi na fiberglass don aiki kusa da layin lantarki.
- Lubricant na igiya Lubricant na tushen ruwa ko silicone yana rage rigakafi a cikin dogon gudu ko ƙananan hanyoyin kwantar da ruwa.
- Masu gwada kebul na USB mai gwada ci gaba na asali ko mai ba da takaddun shaida mafi ci gaba wanda ke bincika raguwa, asarar dawowa, da crosstalk kusa da ƙarshen (NEXT).
- Kayan aikin ƙare Kayan aikin bugun ƙasa, RJ45 crimpers, wire strippers, da kayan aikin matsawa na coaxial.
- Fasteners da gudanar Kayan waya, D-ring, murfin juzu'i, Velcro ties (ba za a taɓa ɗaure zip ties a kan igiyoyin bayanai ba), da kuma teburin igiyoyi.
- Kayan kare kai (PPE) tabarau na tsaro, safofin hannu masu jure yanke, hat din (ginin gini), abin rufe kurciya, da kare kunne idan ana amfani da kayan aiki na lantarki.
- Tsarin lakabi Fitar lakabi ko alamun da aka riga aka buga, mai alama, da takardun shaida.
- Sauran mahimman abubuwa Fitila, mai gano ƙugiya, mai gano ƙarfin lantarki, tsayin mataki, da kayan aikin hannu masu rufi.
Tabbatar da Tsaron Tsaro da kuma Binciken Yanki kafin Aiki
Yadda Za a Gane Hadari
Kowane yanayin shigarwa yana da haɗari na musamman. A cikin gine-ginen kasuwanci, zaku iya haɗuwa da bututun lantarki, allon ƙarfin lantarki, rufin faduwa tare da tayal masu nauyi, da bututun HVAC. A cikin gidaje, haɗari sun haɗa da wayoyi masu rai a bayan bango mai bushewa, azbestos a cikin tsofaffin gini, da wuraren fitarwa marasa ƙasa. Yi tafiya mai zurfi tare da mai gano ƙarfin lantarki na FLT: 1 don gano kewayon rayuwa kafin yin ramuka ko jan wayoyi. Koyaushe tabbatar da cewa an kashe wutar lantarki a kwamitin murƙushewa lokacin aiki a wuraren da ke da wutar lantarki. Yi amfani da hanyoyin kulle / ƙuƙwalwa idan ana buƙata ta hanyar yarjejeniyar aminci.
Dokokin Wuta da Gina
Dokokin gine-gine na gida suna ba da ƙididdigar igiyoyi don tsayayya da wuta. A Amurka, Dokar lantarki ta kasa (NEC) ta bayyana nau'i uku na farko:
- CM (Sadarwa) Babban amfani, mai dacewa don amfani da mazauna inda ake gudanar da kebul a cikin wuraren da ba su cika ba.
- CMR (Riser) Ana buƙatar tsayayyen gudu tsakanin bene; ya cika iyakokin yaduwar wuta.
- CMP (Plenum) Ana buƙatarsa a cikin wuraren sarrafa iska (a saman rufin faduwa, a ƙarƙashin hawa) don mafi ƙarancin hayaki da yaduwar wuta.
Yin amfani da ƙimar da ba daidai ba na iya haifar da haɗarin wuta ko keta buƙatun inshora. Koyaushe bincika lambobin gida kafin zaɓar kebul. Don ƙarin ƙarfin hali da kuma tabbatar da gaba, yawancin masu kwangila suna amfani da kebul na CMP don ayyukan kasuwanci.
Zaɓin Kayayyaki da Shirye-shiryen
Zaɓin Nau'in Kabel da Ya Dace
Kafofin sadarwa na zamani suna da yawa don yin amfani da wayoyin sadarwa na zamani. Saurin gudu da nisa suna ƙayyade nau'in kebul. Ga hanyoyin sadarwar ofis na yau da kullun waɗanda ke buƙatar saurin gigabit, Cat6 ya isa. Idan ana shirin 10GBASE-T (10 Gbps) akan nesa mai tsawo, Cat6a (ƙara) shine zaɓi na yau da kullun. Cat5e ya kasance mai karɓa ga tsarin da aka riga aka kafa amma ba zai iya tallafawa saurin sauri ba. Don dogon gudu sama da mita 100, ana buƙatar fiber optic (mode guda ko yanayin da yawa). Ana amfani da igiyoyin haɗin kai (RG6, RG11) don talabijin kebul, intanet, da tauraron dan adam waɗannan suna da abubuwan jan hankali na kansu, gami da mai jagorar cibiyar da zai iya karya a ƙarƙashin tashin hankali.
Tsarin Hanya da Binciken Hanya
Map da aka ba da shawarar hanyar kebul daga kwantena zuwa fitowar. Ka guji yankunan da ke da igiyoyin lantarki kiyaye aƙalla inci 6 na rabuwa daga layin wutar lantarki don daidaitaccen gudu ( buƙatar NEC) kuma tsallake a digiri 90 don rage tsangwama. Yi amfani da kwandon igiyoyi na yanzu, J-hooks, ko bututu inda akwai. Don sabon gini, daidaita tare da masu aikin lantarki da masu shigar da HVAC don kauce wa rikice-rikice. A cikin sabuntawa, yi la'akari da amfani da wuraren samun damar mara waya don rage yawan igiyoyin. Bayyana hanyar da aka tsara tare da hotuna da bayanan kula.
Bada damar sassauci a ƙarshen biyu (yawanci 10-15 feet a gefen kwandon kwandon, 3-5 feet a fitowar) don karɓar kuskuren ƙare da motsi na gaba.
Hanyar Fitar da Kayan: Mai Amfani da Kayan Fitarwa
Yadda Za a Saita Faya-fayen Kabelu
Sanya reel na kebul a kan wani spindle wanda ke ba da damar juyawa kyauta. Kada kawai ka sanya reel a ƙasa wannan yana haifar da juyawa da yin juyawa. Biya da kebul daga gefen reel (ba a saman ba) don rage tashin hankali. Don dogon gudu, yi amfani da mai jan igiyar waya tare da mai auna tashin hankali. Matsakaicin tashin hankali don yawancin igiyoyin bayanan tagulla shine 25 fam na ƙarfi (kimanin 111 N). Ga igiyoyin fiber optic, matsakaicin ya fi ƙasa da yawa, kusan fam 10 na ƙarfi, kuma dole ne a kula da kebul tare da kulawa sosai. Ƙetare waɗannan iyakokin yana faɗaɗa masu gudanar da tagulla ko lalata zaren gani, wanda ke haifar da matsalolin aiki.
Yin Amfani da Fashin Kifi da Kuma Fitar da Glandula
Don ɓoyewa yana gudana ta bango ko bututu, haɗa tef ɗin kifi daga inda ake nufi zuwa asalin. Sanya kebul ɗin zuwa tef ɗin kifi ta amfani da riƙewa ko madauri mai kyau a kusa da jaket ɗin kebul. Kada ku haɗa da ma'aurata masu jagora na mutum. Don ƙuƙwalwar igiyoyi da yawa, yi amfani da riƙewar waya mai jan hankali wanda ke rarraba tashin hankali daidai. Aiwatar da lubricant na kebul a cikin hanyar shiga da kuma a cikin hanya, musamman a cikin lankwasawa.
Ja da kyau babu ja da baya ko ja da baya. Ja da baya yana haifar da micro-banbanƙyama kuma yana iya jan kwararar daga jaket. Kula da daidaitaccen gudu. Idan kuna amfani da mai jan wuta, saita ƙarfin zuwa iyakar da aka ba da shawarar. Kula da kebul yayin da yake ciyarwa daga reel don gano ƙuntatawa ko juyawa. Idan juriya ta karu ba zato ba tsammani, Dakatar. Kayan ya juya dan kadan kuma bincika toshewa kafin ci gaba.
Gudanar da Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin
Kayan waya na bayanai suna da mafi ƙarancin radius na lankwasawa yawanci sau 4 na diamita na kebul don tagulla, kuma sau 10 don fiber. Ƙarƙashin radius yana karya lissafin ciki na nau'ikan nau'ikan da aka juya, yana haifar da rashin daidaituwa da kuma hasken sigina. Yi amfani da lankwasawa mai zurfi na digiri 90 ko jagororin lankwasawa. Guji tura kebul a kusa da kusurwa masu kaifi, a kan farantin ƙusa, ko ta hanyar ramuka masu ƙyama. Lokacin jan ta hanyar bututu, yi amfani da akwatunan jan a kowane juyawa na digiri 90 kuma iyakance yawan juyawa zuwa biyu a kowace gudu.
Kayan da Za a Yi Gyara
Yadda Za a Ƙulla Ƙungiya
Bayan an cire, toshe kebul ɗin a hankali tare da madaurin Velcro, D-ring, ko igiyoyin igiyoyi waɗanda aka tsara don haɗa bayanai. Zip ties na iya murkushe jaket ɗin kebul kuma ya ɓata nau'ikan masu gudanarwa yi amfani da su kawai a kan sheqa na waje kuma kada ku yi taurin kai. Don madaidaiciyar gudu a cikin kwanonin igiyoyi, shimfiɗa kebul a cikin wani yadudduka. Kada ku haɗa fiye da wayoyi 50 tare da juna sosai, saboda wannan yana ƙara yawan zafin jiki da haɗuwa. Bada sarari don yaduwar iska.
Labari da Takaddama
Label biyu karshen kowane na USB nan da nan bayan jan. Yi amfani da wani m sunan yarjejeniya: misali, FD-1R-05-A ma'ana Floor 1, Room 05, Jack A. Rubuta labels har abada ko amfani da lakabi makera. Create a takarda ko cibiyar sadarwa takardun tare da na USB ID, source patch panel tashar jiragen ruwa, manufa fitowa, na USB irin, da kuma gwajin sakamakon. Wannan takardun ceton mai girma lokaci a lokacin troubleshooting da kuma daga baya motsi, ƙara, ko canje-canje (MACs).
Ka Guji Tushen Shagala
Lambobi na bayanai suna da saurin rikice-rikice na lantarki (EMI) daga igiyoyin wutar lantarki, masu motsawa, fitilun walƙiya, da sauran kayan aiki. Kula da rabuwa kamar yadda aka ba da shawarar ta ƙa'idodin TIA / EIA: aƙalla ƙafa 2 daga kayan aikin walƙiya, ƙafa 3 daga manyan motoci ko janareto, da inci 6 daga layin wutar lantarki na 120V. Lokacin da kewaya igiyoyin wutar lantarki, yi hakan a kusurwar dama don rage haɗuwa da haɗuwa.
Ƙarshen da Gwaje-gwaje
Kashe RJ45 Connectors da Jacks
Bi T568A ko T568B daidaitaccen tsarin waya a duk faɗin shigarwa. Amfani da mazauna gida sau da yawa yana ƙetare T568B, amma cibiyoyin kasuwanci na iya buƙatar daidaitaccen tsari wanda sashen IT ya ƙayyade. Yi amfani da kayan aikin ƙwanƙwasawa mai inganci tare da madaidaicin wuka (110 ko salon Krone). Tabbatar da cewa masu gudanarwa suna zaune sosai kuma ba a lalata su ba. Don toshewa na zamani, saka wayoyi a cikin tsari mai kyau kuma yi amfani da mai ƙwanƙwasawa wanda aka tsara don ma'aunin kebul (23 AWG don Cat6, 24 AWG don Cat5e).
Yin Gwada Kowane Gudun
Bayan ƙare, gwada kowane kebul tare da mai gwada cibiyar sadarwa. Aƙalla, bincika don ci gaba (watau duk wayoyi takwas da aka ƙare daidai a ƙarshen duka biyu). Masu gwadawa masu ci gaba na iya auna tsawon, asarar sakawa, asarar dawowa, NEXT, da PSNEXT. A cikin saitunan kasuwanci, ana buƙatar gwajin takaddun shaida sau da yawa don tabbatar da aikin zuwa Cat6 ko Cat6a ƙayyadaddun. Bayyana duk sakamakon gwajin; dole ne a sake ƙare ko maye gurbin wayoyi mara kyau. Abubuwan da suka fi dacewa sun haɗa da ma'aurata masu rabuwa, ma'aurata masu juyawa, gajerun hanyoyi, da tsayi mai yawa.
Ko da a daya m ƙare iya kawo saukar da dukan cibiyar sadarwa sashe. gwaji ba tilas ne shi ne na karshe ingancin tabbatarwa mataki. BICSI shigarwa Standards Shawarwari
Yadda Za a Warware Matsaloli da Suka Shafi
- ]Saurin saurin cibiyar sadarwa: ] Bincika tsawon igiya wanda ya fi mita 100 (328 ƙafa). Bincika wayoyin ƙare. Bincika lalacewa ko kinks a cikin gudu.
- Haɗin lokaci-lokaci: Sau da yawa ana haifar da haɗin da ba a daidaita ba, lalacewar lalacewa, ko ɓarkewar ɓangare saboda yawan ƙarfin lantarki. Sake ƙarewa da gwaji.
- FTL:0: Fitaccen crosstalk: Mai yiwuwa daga ƙuntataccen lankwasawa, igiyoyi masu ɗaure tare da layin wutar lantarki, ko mara kyau mai kyau. Sake turawa ko maye gurbin.
- Babu haɗi: Yi amfani da toner don bin diddigin kebul ɗin kuma sami fasa. Bincika ci gaba ta kowane fil. Maida idan an murkushe ko an cire katako.
- Matsalolin ƙasa: FLT:1 Kable masu kariya dole ne a ƙasa kawai a ƙarshen ɗaya (yawanci a cikin kwandon patch) don kauce wa madaukai na ƙasa waɗanda ke haifar da hayaniya ko tsangwama.
Abubuwan da Za a Yi la'akari da Su na Musamman ga Kasuwanci da na Zama
Yanayin Kasuwanci
Dole ne a yi amfani da allon hawa da kuma karewa bayan sa'o'i don kauce wa katse ayyukan kasuwanci. Takaddun shaida suna da mahimmanci don kiyayewa da faɗaɗa gaba. Bugu da ƙari, cibiyoyin kasuwanci na iya buƙatar caji mai cikakken darajar a cikin sararin samaniya don kula da iska.
Yanayin da Za a Yi Rayuwa
Aikin zama yana da sassauƙa amma yana da kalubalen kansa: ƙarancin sararin rufin rufin, rufi, da kuma lalata wayoyi da ke akwai. Masu gidaje galibi suna son ɓoye gudu a cikin bango. Yi amfani da tsofaffin akwatunan aiki da ƙananan ƙarfin lantarki don shigar da tashoshi. Yi hankali kada ku lalata ƙuntatawa wuta ko rufin rufi. A wurare da yawa, har yanzu ana buƙatar mai ba da lasisi mai ƙarancin ƙarfin lantarki. Koyaushe bincika lambobin gida kafin yin hako ta hanyar sanduna ko sanduna. Labeling ya fi sauƙi amma har yanzu ana ba da shawarar don tsarin gida mai kaifin baki.
Amintaccen Lokaci da Tabbatar da Lokaci Mai Zuwa
Don tabbatar da cewa kebul na bayanai ya kasance abin dogaro har tsawon shekaru goma ko fiye, shirya don ci gaba. Sanya aƙalla ƙarin igiyoyi biyu a kowane wuri don faɗaɗa gaba. Yi amfani da Cat6a ko mafi kyau, koda kuwa buƙatun na yanzu sun fi ƙasa. Cat6a yana tallafawa 10 Gbps har zuwa mita 100 kuma yana da kariya mafi kyau ga ƙetarewar baƙo. Guji gudanar da igiyoyi a cikin hanya ɗaya da manyan layin wutar lantarki (kamar 208V ko 480V). Don fiber optic runs, shigar da pre-ƙetare igiyoyi tare da jawo rated connectors don kauce wa filin ƙare ciwon kai. Kula da tsabta na gaba da tsarin kula da igiyoyi wannan zai sa sauyi sauyawa da kuma rage hadari disconnection.
A ƙarshe, sake gwadawa na lokaci-lokaci bayan shekaru da yawa zai iya gano lalacewa daga abubuwan muhalli kamar danshi, zafi, ko lalacewar jiki. Sabunta takaddun shaida ya kamata su bi duk wani sake turawa ko sake ƙare. Tsarin igiyoyi mai tsari, da aka shigar da kyau shine dukiya mai tsawo wanda ke biya kanta a cikin ragewa lokaci da kuma sauƙin kulawa.
Ƙarshen
Tsaro da inganci na shigar da igiyoyin bayanai na da muhimmanci ga amincin cibiyar sadarwa. Ta bin ƙa'idodin aminci masu tsauri, zaɓar igiyoyi da kayan aiki masu kyau, tsara hanyoyin da kyau, amfani da fasahohin janyewa masu kyau, tabbatar da alamun da aka lakafta daidai, da kuma gwada kowane gudu, kuna tabbatar da haɗin kai mai ƙarfi a cikin yanayin kasuwanci da na zama.
Don ƙarin karatu, bincika BICSI Telecommunications Standards for best practices, da kuma FLT:2 NEMA don kula da kebul. Bugu da ƙari, jagororin jagororin Fiber Optic Association na FLT:4 suna da kyau sosai don shigar da fiber. Koyaushe ku kasance cikin zamani tare da lambobin gida da ANSI / TIA don tabbatar da bin doka da aminci.